Axess Ready CM-1115-RT-AR Guía de instalación Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
CM-1115(20)-RT-AR User Manual
Page 20
VII. Command Line Interface (CLI) Protocol
(continued)
AutoPing Commands
Command
Description
Admin
Fact Def
get autoping Returns all AutoPing settings currently in use.
Example:
AutoPing 1 AutoPing 2
IP Address: 10.1.2.36 0.0.0.0
Frequency: 60 10
Fail Count: 3 3
Status: OK OK Trigger Count: 0 0
-------------------------------------- Mode: Single
Action: On-Latch
Ok
Yes
set autoping < 1 | 2 > ipaddress < dotted decimal >
Sets the IP address to be pinged for AutoPing 1 or
2
Yes 0.0.0.0
set autoping < 1 | 2 > frequency < 1-999 > Sets the frequency (how often the ping is sent) for
AutoPing 1 or 2 in seconds.
Yes 10
set autoping < 1 | 2 > failcount < 1-999 > Sets the number of consecutive failures the
AutoPings must detect before the AutoPing
considers the pinged device to be failed.
Yes 3
set autoping mode < single | and | or >
Sets single AutoPing (AutoPing 1) or two AutoPing
relationship AND or OR.
Yes
AND
set autoping action < none | on-latch | on-follow | off-
latch |
off-follow | cycle | cycle-once >
Sets the action to be performed when the AutoPing
is triggered.
Yes None
User Commands
Command
Description
Admin
Fact Def
set password < user | admin > < old > < new > < repea
t
Sets the password of the User or Administrator. Yes user | admin
Vista de pagina 20